loading

Sincerity Group | Coriolis flow meter manufacturers| 

Interference Factors and Treatment Methods in Mass Flow Meter Measurement

by:Sincerity Group     2022-08-11
Abstract: The information on the interference factors and processing methods in the measurement of mass flow meters is provided by the excellent manufacturers of flow meters and flow meters. We all know that mass flow meters can directly and accurately measure the quality of fluids, as well as density and temperature. In the use of mass flowmeters, the measured results will be more accurate only if the mass flowmeters are not affected by interference factors. Tianchen. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the interference factors and processing methods in the measurement of mass flow meters. We all know that mass flow meters can directly and accurately measure the quality of fluids, as well as density and temperature. In the use of mass flowmeters, the measured results will be more accurate only if the mass flowmeters are not affected by interference factors. Tianchen Borui summarizes the interference factors and processing methods in the measurement of mass flow meters, and now shares them with you. 1. The influence of vibration on the accuracy of the mass flowmeter. Treatment method: Avoid vibration interference. If it is unavoidable, isolation measures should be taken to isolate the flowmeter from the vibration interference source. 2. The influence of electromagnetic interference on the accuracy of mass flowmeter. Treatment method: The mass flow meter should be installed away from equipment that generates large magnetic fields such as large transformers and motors. 3. The influence of installation stress on the accuracy of mass flowmeter. Treatment method: a. The installation specification should be strictly followed when the flowmeter is installed. b. After the flowmeter is installed, call it out with the hand-held communicator or on the transmitter interface.“Zero menu”And record the factory zero preset value, and then observe the zero value after zero adjustment. The two values ​​before and after should be guaranteed to be in the same order of magnitude. If the difference between the two values ​​is large, it means that the installation stress is too large and should be reinstalled. 4. The influence of the gas contained in the oil on the accuracy of the mass flowmeter. Treatment methods: a. Improve the working conditions of the oil, so that the bubbles contained in it are distributed as evenly as possible to meet the requirements of the normal measurement of the flowmeter; b. Install an air eliminator upstream of the mass flowmeter to minimize the phenomenon of gas-liquid mixing; c. Install in strict accordance with the installation specifications of the mass flowmeter: measure the oil medium flow tube and install it downwards 5. The influence of temperature changes on the accuracy of the mass flowmeter. Processing method: a. The influence of temperature on the metal elasticity of the measuring tube of the flowmeter can be solved by setting the temperature correction coefficient; b. The influence of temperature on the zero point stability, in practical applications, it is necessary to adjust the mass flowmeter under the operating temperature condition. Perform field zeroing to minimize impact. 6. The influence of pressure change on the accuracy of mass flowmeter. Treatment method: For oil products with large changes in transmission pressure and custody transfer, it is necessary to install a pressure transmitter downstream of the flowmeter to perform pressure compensation in real time in the form of software. 7. The influence of oil density and viscosity on the accuracy of mass flowmeter. Treatment method: The flowmeter should be used to measure a single oil product or oil with little difference in density. The mass flowmeter used for the transfer of bulk oil products must be calibrated on-line and equipped with an on-line density meter. 8. The influence of damage or corrosion of the measuring tube on the accuracy of the mass flowmeter. Treatment method: a. Install a corresponding filter at the front end of the flow meter to prevent foreign matter from entering; b. Use a flow meter of special material. Tianchen Borui is currently the smallest manufacturer of mass flow meters in China, which stabilizes the production process of mass flow meters. The core sensitive unit adopts mechanical tooling + vacuum brazing technology to ensure product consistency. The precise matching control of the measuring tube ensures the symmetry of the double tube structure. Measuring tube strain relief technology reduces sensor drift. Vibration balance control technology ensures minimal sensor coupling vibration. The aging technology of the whole machine ensures the stability of the system and reduces the drift of the system. Ensure stability during measurement. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Interference factors and treatment methods in mass flow meter measurement'
As a entrepreneur, being trapped in a company under multiple quality problems never appealed to Beijing Sincerity Automatic Equipment Co., Ltd.
If you are interested in , click Sincerity Flow Meter to see some items with features that you will be amazed at.
Beijing Sincerity Automatic Equipment Co., Ltd will need to find one that fits our needs and budgets, and still turns out a quality product.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: