loading

Sincerity Group | Coriolis flow meter manufacturers| 

Intelligent electromagnetic flowmeter scale installation and use

by:Sincerity Group     2020-10-15
Abstract: the intelligent electromagnetic flowmeter scale installation and use note information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Preface: this article focuses on the intelligent electromagnetic flowmeter during the installation process need to be aware of a few small details, correct installation of the intelligent electromagnetic flowmeter late precision stability and maintenance plays an important role. 1, pay attention to measure the fluid. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the intelligent electromagnetic flowmeter scale installation and use note article details. Preface: this article focuses on the intelligent electromagnetic flowmeter during the installation process need to be aware of a few small details, correct installation of the intelligent electromagnetic flowmeter late precision stability and maintenance plays an important role. 1, pay attention to measure the fluid nature of the fluid has a certain electrical conductivity, electrical conductivity must also be distributed evenly in the fluid, so the intelligent electromagnetic flowmeter sensor installation should be avoided in conductivity uneven places, ( Such as: as far as possible need to join other fluids in the fluid, is on the downstream side of the sensor to add) ; 2, when installation should pay attention to outwit the required 1) production Must be installed in mixed, measuring mixing liquid liquid never have separate production; Two-component liquid of measurement, avoid installation on the downstream side of the uneven mixture of; When measuring chemical liquid, need to install on the downstream side of the reaction fully; 2) , try to avoid pipeline in negative pressure; 3) As far as possible, choose to install on the smaller pipe vibration; 4) , try to avoid intelligent electromagnetic flowmeter near large mechanical and electrical equipment, so as not to cause electromagnetic interference; 5) , try to install the sensor in facilitating grounding produced by it; 6) And try to avoid a strong corrosion of gas around the intelligent electromagnetic flowmeter; 7) , installation environment humidity controlled in the range of 10% ~ 90% as far as possible; 8) And try to avoid the sun direct illuminate for a long time; 9) , avoid the baptism of the rain shower, good waterproof measures; 3, straight pipe installation requirements in order to achieve the intelligent electromagnetic flowmeter metering precision, straight pipe sensor still need to meet certain requirements, but relatively low, not as high as vortex flowmeter, specific can consult the table below: 4, the intelligent electromagnetic flowmeter sensor installation location matters needing attention of installation direction can be horizontal, vertical, inclined installation, in solid-liquid two-phase flow measurement, the sensor is installed vertically, as far as possible because when fluid flows from bottom to top, can effectively avoid attrition phenomenon seriously, 5, and grounding of the intelligent electromagnetic flowmeter sensor must be grounded, and grounding resistance should be in 100 & Omega; The following, if the sensor installed on the cathodic corrosion of pipeline, in addition to the ground, also need 16 mm & sup2; Copper conductor, bypass on the flange on both sides of the sensor, isolates cathode current sensor with the conclusion: the installation of the intelligent electromagnetic flowmeter note although trival, but notice above when installation, can avoid all later in the operation of the faults. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd who is highly knowledgeable about manufacturing as well as selling and confident in our ability to create finest products as mass flow meter coriolis density meter.
Beijing Sincerity Automatic Equipment Co., Ltd will expand our presence in direct selling and lead the reinvention of the channel, offering an entrepreneurial opportunity that delivers superior earnings, recognition, service and support, making it easy and rewarding to be affiliated with Sincerity and elevating the image of our industry.
need fuel for energy,while u shape coriolis mass flow meter do not.
In order to obtain the most suitable for your fork density meter manufacturer, you need to contact qualified suppliers which can produce super quality to your specifications and offer a friendly price.
Through our distribution and marketing competencies, Beijing Sincerity Automatic Equipment Co., Ltd provides creative, customized, solutions for our customers. As a result, we achieve superior profit growth as the mass flow meter company of choice.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: