Abstract: The information on the installation requirements of the orifice flow meter is provided by the excellent flow meter and flow meter production and quotation manufacturers. 1. Requirements for the pipeline when the orifice flowmeter is installed: 1. The orifice flowmeter should be installed with a section of measuring pipe, at least keep the same diameter straight pipe section of the first 10DN and the rear 5DN to improve the measurement accuracy. 2. The inner diameter of the impulse piping, the length of the piping and the contamination of the medium. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the details of the installation requirements of the orifice flowmeter. 1. Requirements for the pipeline when the orifice plate flowmeter is installed: 1. The orifice flowmeter should be installed with a section of measuring pipe, at least keep the same diameter straight pipe section of the first 10DN and the rear 5DN to improve the measurement accuracy. 2. The inner diameter of the pressure-inducing pipeline is related to the length of the pipeline and the degree of contamination of the medium. Usually, a pipe with an inner diameter of 8-12mm is used within 45 meters. 3. If a valve needs to be installed before and after the orifice flowmeter, it is best to choose a gate valve and fully open it during operation; the regulating valve should be in the pipeline after 5DN downstream. 4. The pressure-inducing pipeline should be supported by a firm bracket. The two pressure-inducing pipelines should be as close to each other as possible and away from the heat source or vibration source. When measuring the water vapor flow, they should be wrapped with thermal insulation materials. ) Add heat tracing pipe to prevent icing. When measuring dirty flow, an isolator or settler should be attached. 5. The single-phase fluid state must always be maintained in the impulse piping. When the measured fluid is gas, all the pressure piping (including the pressure chamber of the differential pressure gauge) is gas phase; when the measured fluid is liquid, all the pressure piping is liquid phase, and there must be no air bubbles. For this reason, a drain valve should be installed at the lowest point of the pressure piping or an exhaust valve should be installed at the highest point, and special attention should be paid when the differential pressure transmitter is newly installed or repaired. 6. When measuring the liquid flow, the horizontal section of the impulse pipe should be in the same horizontal plane. If the throttling piece is installed on the vertical pipeline, the short pressure pipes are separated by a certain distance (the direction of the vertical line), which will affect the zero point of the differential pressure transmitter and should be passed through.“Zero migration”to correct. 2. Inspection before installation of the orifice flowmeter pipeline: Before installing the orifice plate flowmeter, carefully check whether the number, position number, and specification of the standard orifice plate are consistent with the pipeline conditions, flow range and other parameters. Note that near the pressure taking port marked with“+”One end should be connected to the fluid upstream section, marked with“—”One end should be connected to the downstream pipe section of the fluid. For a new pipeline system, the standard orifice plate must be installed after the line is scanned, so as to prevent the debris in the pipe from clogging or damaging the standard orifice plate, which will reduce the measurement accuracy. The centerline of the standard orifice plate should be coaxial with the centerline of the pipe. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Installation Requirements for Orifice Flow Meters'
u shape coriolis mass flow meter mass flow meter, device for producing low flow turbine flow meter, rosemount vortex flow meter, and other coriolis mass flow meter emerson, consisting of endress hauser ultrasonic flow meter.
Beijing Sincerity Automatic Equipment Co., Ltd is a reliable company that offers wonderful . In addition, the company also provides related components to make it more efficient. To know more, go to Sincerity Flow Meter.
mass flow meter offers the opportunity for improved manufacturing and product’s data collection, as well as direct feedback, enabling companies to better understand their consumer base and respond accordingly.
Beijing Sincerity Automatic Equipment Co., Ltd's core technology of mass flow meter enables us to understand and utilize in a right way.
Beijing Sincerity Automatic Equipment Co., Ltd’s model also predicts (i) a positive effect of management on firm performance; (ii) a positive relationship between product market competition and average management quality (part of which stems from the larger covariance between management with firm size as competition strengthens); and (iii) a rise (fall) in the level (dispersion) of management with firm age.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com