Abstract: The installation requirements information of Delbar flowmeter and other flowmeters are provided by excellent flowmeter and flowmeter manufacturers and quotation manufacturers. Installation requirements of Delbar flowmeter 1. For the I-type sensor, the detection rod has been welded into a piece of pipeline, and the sensor must be installed in the direction of fluid flow. It is required that the inner diameter of the process piping is the same as the inner diameter of the sensor, or at least straight upstream. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the details of the installation requirements of Delba flowmeters and other flowmeters. Installation requirements of Delbar flowmeter 1. For the type I sensor, the detection rod has been welded into a piece of pipeline, and the sensor must be in the direction of fluid flow during installation. It is required that the inner diameter of the process pipeline is the same as the inner diameter of the sensor, or at least the angle between the axis of the sensor and the axis of the pipeline is as zero as possible within the required length of the upstream straight pipe section. 1. For the I-type sensor, the detection rod has been welded into a piece of pipeline, and the sensor must be installed in the direction of fluid flow. It is required that the inner diameter of the process pipeline is the same as the inner diameter of the sensor, or at least the angle between the axis of the sensor and the axis of the pipeline is as zero as possible within the required length of the upstream straight pipe section. For other types of sensors, the detection rod is inserted into the process pipeline. During installation, in addition to the total pressure hole facing the direction of flow velocity, it must be ensured that the sensor detection rod is perpendicular to the axis of the process pipeline, and its allowable position angular pressure deviation. The angle between the center of the total pressure hole of the sensor and the axis of the pipeline should be less than 7°The sensor detection rod is inserted into the bottom along the diameter of the pipe, and its angular deviation is less than 7°The vertical pipeline sensor can be installed at any position along the pipeline circumference 360 on the horizontal plane of the pipeline. The high and low pressure impulse pipes should be on the same plane, as shown in Figure 6(a); when measuring liquid, it should be installed inclined downward; When measuring the vapor of the gas, it should be installed at an upward slope. 2. Since the sensor is based on the velocity area method, the approximate integral theory is used to describe the straight pipe section with more points. distribution equation, and is established under the conditions of a fully developed velocity distribution. Therefore, in order to obtain an ideal distribution, there must be a certain length of straight pipe section serial number before and after the sensor. The flow sensor is installed on the upstream side A and the downstream side B. There are rectifiers and no rectifiers on the same plane and different planes. 1. There is a 90°Elbow or tee 6D7D9D3D; 2. There are two 90 in the same plane°Elbow 8D9D14D3D; 3. There are two 90 in different planes°Elbow 9D19D24D4D; 4. Pipe diameter change (retraction or expansion) 8D8D8D3D; 5. Partially opened gate valve, ball valve or other throttle valve 8D8D8D3D. Note: (1) In the table“D”is the inner diameter of the pipe. (2) In the case of insufficient pipeline section, the upstream should account for 70% of the total length of the pipeline, and the downstream should account for 30%. At this time, a stable indication value can still be given, but the accuracy is reduced. The device that clamps the sensor should ensure no leakage, no looseness, and no displacement. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Installation Requirements for Delba Flow Meters and Other Flow Meters'
Beijing Sincerity Automatic Equipment Co., Ltd's products comply fully with all compatible producing regulations.
Beijing Sincerity Automatic Equipment Co., Ltd didn’t receive any negative feedback from our customers before, which proves that customers have faith in us.
With innovative technology, our professionals can spend more time focused on strategies that will improve mass flow meter’s quality and deliver a more positive customers experience.
The unique connections between mass flow metermanufacturing and customers happen when you find ways to relate on a more personal and engaging level that goes beyond a product.
In business, mass flow meter means cultivating brand loyalty; once someone is working with a product or using a service, they are more likely to commit to paying for Sincerity again.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com