loading

Sincerity Group | Coriolis flow meter manufacturers| 


Installation of vortex flowmeters what are the requirements? Electromagnetic flow meter how much?

Vortex flowmeter is mainly used for industrial piping medium fluid flow measurement, such as gas, liquid, steam and other media. In order to ensure the accuracy of the meter, vortex street flowmeter installation need in strict accordance with the requirements, the next Beijing tzu chi in kaifeng industrial control instrument co. , LTD. , said the specific installation requirements. Vortex street flowmeter installation requirements: 1, select installation location should avoid strong power equipment, high-frequency equipment, strong power switch device; To avoid the influence of high temperature heat source and the radiation source, to avoid strong vibration and strong corrosive environment and so on, at the same time to consider easy installation and maintenance. 2, the sensor can be installed in the ( Indoor or outdoor) Horizontal, vertical or inclined pipes. But when measuring the liquid, the pipe must be full of liquid, namely: when installed in vertical or inclined pipe, the flow of liquid should flow from bottom to top. 3, sensor installation of straight pipe should be as far as possible with the sensor size ( DN) Consistent. If not consistent, should use slightly larger diameter than the sensor size, and the error to 3% or less is not more than 5 mm. 4, upstream and downstream straight pipe must have enough. If the sensor installed upstream of point on the same plane has two 90. Elbow, are: straight pipe upstream of 25 d, or downstream straight pipe section 5 d or higher. If the sensor installed upstream of point in different plane has two 90. Elbow, are: straight pipe upstream of the 40 d or higher, the downstream straight pipe section 5 d or higher. Regulating valve should be installed on the downstream side of the sensor outside 5 d, if must be installed in the upstream of the sensor, the sensor straight pipe upstream should be not less than 50 d, downstream should be not less than 5 d. 5, selection of pressure and temperature measuring points, according to the needs of measurement, to be near the sensor to measure the pressure and temperature, the pressure measuring point should be 3 - of the downstream of the sensor 5 d, temperature measuring points should be 6 - of the downstream of the sensor 8D。 Superfamily shihua is is a company specializing in the research, development, production and sales all kinds of liquid level, flow control and material level control of high-tech enterprises, the main products: electromagnetic flowmeter, ultrasonic flowmeter, vortex flowmeter, turbine flowmeter, orifice flow meter, etc. , in accordance with the needs of each client product development, we sincerely invite the broad masses of new and old friends to choose products.

Sincerity allocates customer service resources to the platform where their customers are most vocal.

To be the safest, most progressive domestic mass flow meter, relentless in the pursuit of customer and employee excellence.

Digging into our roots and acknowledging out heritage can be fruitful on both a high-quality and professional level of mass flow meter.

Although the core manufacturing factor of mass flow meter is high technology, smart customers know that we need to enhance our material quality and producing standard.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect