loading

Sincerity Group | Coriolis flow meter manufacturers| 

Important points using metal pipe flow meter scale

by:Sincerity Group     2021-04-14
Abstract: the use of metal tube float meter scale attention points of the information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Weinan and shunda metal flow meter, flow meter manufacturers one-piece, both inside and outside is used in the main tube forming, no dead Angle measurement, small pressure loss, magnetic element is not affected by the magnetic field, the indicator modular installation, the viscosity, density, temperature and medium. More flow meter manufacturers choose model price quote you are welcome to inquire, the following important points is the use of metal tube float meter scale article details. Metal flow meter, flow meter manufacturers one-piece, both inside and outside is used in the main tube forming, no dead Angle measurement, small pressure loss, magnetic element is not affected by the magnetic field, the indicator modular installation, of medium viscosity, density, temperature, pressure multistage correction calibration. Compared with the traditional flowmeter, has the advantages of high precision, good repeatability, small services. When use, however, we also need to pay attention to several aspects: first, before the installation of metal tube float flowmeter must will pipe welding slag, clean up the clutter. Second, in order to ensure of metal tube float flowmeter measurement accuracy, should increase in the inlet side flowmeter in not less than 10 dn of straight pipe, outlet not less than 5 dn straight pipe, when measuring the regulating valve must be installed on the downstream side of the meter. Third, if the measured medium for big pulsating flow or two phase flow, should be installed upstream of the metal tube float flowmeter buffer to eliminate or weaken the pulsation, ensure the flow of the medium is single-phase stable, at the same time, suggested that the flowmeter zui good use of the damping type. Fourth, if the measured medium is dirty or containing magnetic particles, filters should be installed at upstream of metal tube float flowmeter or magnetic filter. Five, the installation of metal tube float flowmeter should be able to properly support the pipeline vibration or reduce the axial load meter, it should increase the support of fixed flow meter. Sixth, to facilitate the maintenance of metal tube float flowmeter, magnetic filter cleaning and user line maintenance on a regular basis, it is recommended to use the bypass pipe as shown. Seven, when metal pipe flow meter is used for gas measurement, shall ensure that the pipe work pressure not less than five times the flow pressure loss, the flowmeter can stable normal action. Eight, the electric remote transmission and take alarm limit switch tube flow meter before use, open the cover, according to the connection here is correct. Unscrew the limit switch for alarm type of screw, the user according to the need to set limit alarm position, and tightening the screws, used after recovery. Nine, according to the instrument indicator of warning signs, prevent float vibration resistance moving parts in the transportation, recovery before using the instrument. Ten, if open the metal tube float flow timing, no pressure or due to the pipe system has not yet reached instrument using normal working pressure, must be slowly open the valve, until the system is normal, the instrument can use, otherwise easy to cause a pointer to beat or float suddenly hit and damage phenomenon. Is eleven, user when using, if the current body of density and water is not at the same time, or the parameters of the gas being measured and working condition and the manufacturer shall not deal with metal flow meter readings are value for conversion. Flow meter manufacturers insist & other; Science and technology, innovation, quality, service & throughout; The development of policy, continue to uphold & other; Make industry aircraft carrier, contribution to national economy & throughout; Purpose, to high-quality products, preferential prices, excellent services actively participate in market competition, we sincerely with friends from all walks of life, new and old customers sincere cooperation, create brilliant. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd is devoted to satisfy our customers with a wide array of the finest using experience.
For more advice on tips, please visit our website Sincerity Flow Meter. Do not hesitate to contact us if you are interested.
In the boundless Chinese market, there are a number of enterprises that provides fork density meter manufacturer mass flow meter of their own brand over the years, but few have won more support from customers on the international stage than Sincerity.
Our company specializes in selling mass flow meter as well as providing relevant services.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: