Abstract: the import of ultrasonic flow meter scale experimental data analysis and summary of information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. In the ultrasonic flowmeter industry at present, good and evil people mixed up, on a BBS meter industry, published their different views and opinions. At the end of the technological exchange, number measurement tests with a water authority under the invitation of Shanghai's escape intelligent instrument. More flow meter manufacturers choose model price quote you are welcome to inquire, here is imported ultrasonic flowmeter scale experimental data analysis and summary of the article details. In the ultrasonic flowmeter industry at present, good and evil people mixed up, on a BBS meter industry, published their different views and opinions. At the end of the technological exchange, number measurement tests with a water authority under the invitation of Shanghai's escape intelligent instrument engineering test with the company acting several product engineer together with several other companies entered the stage of experiment. In field conditions: * a sewage treatment plant, drainage pipeline, DN1800mm, carbon steel pipe, the outer wall of pipeline with non-woven fabric and asphalt coating; In order to form the attack, as no other brands and record the result of the experiment, objective truth in this, list only agent of my company for the performance of the ultrasonic flowmeter and the data. 1, the premise: don't get rid of the outer wall of pipeline coating, SY - 320 ultrasonic flowmeter, no signal and the readings; FLEXIM F601, ultrasonic flowmeter signal is normal, normal reading, the reading values and the error of the electromagnetic flowmeter to + 3 at the scene. 15%. 2, the premise: remove the outer wall of pipeline coating, SY - 320 ultrasonic flowmeter, a signal, reading is normal, with the ultrasonic flowmeter in the alignment error is + 3. 7%, considering the error of the ultrasonic flowmeter, and the error of the electromagnetic flowmeter, the readings, barely acceptable; FLEXIM error of the ultrasonic flowmeter for + 0. 52%. Experimental conclusion: through this experiment, it is easy to analyze, for the measured results directly affect working conditions on site, after the experiment, a drainage management office under the water authority, director of the view of present regrets: later in the process of field measurements, absolutely can't to save trouble, in order to fast, not working condition for processing, this condition does not handle the spot test, is to all, water processing, and the irresponsibility of existing equipment. Second test site conditions: high temperature test site, a dyeing factory, DN219, carbon steel pipe, medium for heat conduction oil, the temperature is 310 degrees, because in view of the high temperature fluid test, only to test the high temperature fluid FELXIM ultrasonic flowmeter, the use is different people the same set of equipment operation, measured in the same condition. Group A: some technical personnel of the ultrasonic flowmeter, watching my company operating FLEXIM ultrasonic flowmeter, and then the operation. Group B: Shanghai's escape intelligent instrument and technical personnel, has skilled operation FLEXIM ultrasonic flowmeter experience, for the high temperature fluid test, gas medium test experience. First B team operation, after five minutes of pipe surface treatment, high temperature nearly 10 minutes of guided wave plate installed, 5 minutes of flow sensor installation debugging with the host, the signal is 4, is very good, reading is stable, and some plug-in table alignment error for the site: - 0. 475% in group B, personnel in the process of operation, A group to view and record the operation steps. A group began operations, after nearly 30 minutes of installation and debugging, data out, but the readings with the standard table error is + 2 by default. 65%; Through the guidance of professional group B, group A personnel A second independent installation and debugging, zui reading out, after reading and the error of the standard table as - at this time 0. 45%. The experimental conclusion: working condition of the same, the same equipment, different measurement, the difference in effect. When doing the flow test, especially for metrology units, such as boiler pressure vessel inspection institute, measurement testing by the third party inspection agencies, must through the test of professional guidance and training, can play the precision of the instruments and function, through professional and technical personnel training and exchange, instrument using smooth sailing, purchase to achieve the effect of instrument. The above experimental analysis, for your reference only, in the process of ultrasonic flowmeter selection, must according to the actual working condition, the actual application of selection, there is no law. Only under the right conditions, choose appropriate ultrasonic flowmeter, can achieve good zui, if the selection of related problems, you can call or consulting professional and technical personnel of our company. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd's products, whether interim or permanent, comply fully with all appropriate producing regulations.
We are proud to be one of the largest suppliers out there. You will love what we offer for your mass flow meter solution. Check our website at Sincerity Flow Meter or call to talk to our customer service department with any questions you may have.
We afford not only the best product but also the comprehensive service, satisfy the customer's demands.
Rewards and discount programs give customers more reason to come back for mass flow meter again, especially in the competitive retail and services markets.
A wholesaler should have many fork density meter manufacturer based products that could help you if you have a v shape coriolis mass flow meter problem. It is better to treat the problem early rather than have to deal with it later. Beijing Sincerity Automatic Equipment Co., Ltd is your best choice.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com