Sincerity Group | Coriolis flow meter manufacturers| 


Huawei sailing stationary ultrasonic flowmeter is scale installation guide

Abstract: huawei sailing stationary ultrasonic flowmeter is scale installation guide information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Stationary ultrasonic flowmeter velocity difference method is used to realize the measurement of water, because the site installation environment, pipe material and parameters, sensor, the influence of such factors as measurement accuracy is often lower than the nominal value, sometimes the error is bigger, and manufacturer. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a huawei sailing stationary ultrasonic flowmeter is scale installation guide article details. Stationary ultrasonic flowmeter velocity difference method is used to realize the measurement of water, because the site installation environment, pipe material and parameters, sensor, the influence of such factors as measurement accuracy is often lower than the nominal value, sometimes the error is bigger, combined with more than ten years of work experience, its the influence factors are discussed in this paper, only eliminate various unfavorable factors, to improve the measurement accuracy. 1, sensors, ultrasonic flowmeter installation, depending on the environment and measurement probe into Z, V, X, measuring sensor installation method selection principle is: when the water along the pipe axis parallel flow, select Z method installation; When the direction of flow and pipe spool is parallel or piping installation place is restricted, the transducer installation interval by the methods of V and X, in does not affect the reception, V method measurement accuracy is higher than the Z method. The distance between the two sensors have strict requirements, must be in accordance with the provisions, the size of the installation, the installation of different distance between the different influence on measurement accuracy, some even error is very large. 2, the influence of the parameter input pipe after installation of fixed type ultrasonic flowmeter, the meter must be input parameters such as pipe diameter, wall thickness, in the pipes under the condition of constant change of input parameters, the diameter of the input error, the error of the measurement result will expand 2 times, the wall thickness is closely relative to input error and measurement error, but the influence on measuring result is not very big 3, the influence of the installation environment fixed ultrasonic flowmeter installation, general requirements upstream and downstream flow meter has a diameter of more than five times as much as 10 times and straight pipe, to ensure that the flow pattern of the measured medium meets the demand of precision instrument, site installation use, often can't find meet the requirements of installation position. Lack of straight pipe lead to different measuring errors, and less impact on the accuracy of the downstream straight pipe, the upstream side when there are more than three times the pipe diameter straight pipe can be used basically met, when the straight pipe upstream is not enough, such as loading forms after elbow, valve, pump valve, general performance for the positive error. 4, the influence of lining and piping material measurement into the lining of piping material input error, can cause calculation error of probe installation distance, make the ultrasonic wave incident Angle error, reduce the measurement accuracy, serious when impact signal and Settings, and so cannot be measured. Pipe lining to measure the impact of stems mainly from its caused the change of the actual diameter, lining to reduce the water area, through flow velocity conversion corresponding small, measurement error is proportional to the pipe cross-sectional area changes, such as the lining is too thick and Settings are ignored or clearance with the pipe wall is generally detection or signal error, so when measuring the thickness of lining material and shall faithfully accurate input. Pipe and lining village environment measurement reflects the influence of the difference in the velocity of sound waves in a variety of medium, if the material is greater than the actual sound set of sound velocity, the measurement results are small and large conversely. 5, and other external factors, coupling agent, signal cable stationary characteristics of ultrasonic flowmeter and the error analysis of the impact of the portable ultrasonic flowmeter measurement, it can be seen that zui to large extent to ensure the accuracy of the flowmeter measurement, also must pay attention to the following: sensors installed in the wall clean; Sensor installation position should be as much as possible in the upstream, bend bend axis plane to obtain smooth bend distortion after relatively close to the average; Sensors installation and pipe wall reflection in must avoid interface and weld; Sensors installed in pipe lining and scale can't be too thick; Coupling agent must be used. Stationary ultrasonic flowmeter - Huawei sailing automation instrument above is all there is in this article, you are welcome to inquire me factory flowmeter selection, quotation, etc.

The average consumer is always looking for ways to save money while finding out solutions, is designed for killing two birds with one stone, providing a perfect solution to mass flow meter problems.

Beijing Sincerity Automatic Equipment Co., Ltd will provide branded products and services of superior quality and value that improve the lives of the world’s consumers.

This is crucial when you need to maintain innovative information in mass flow meter.

Beijing Sincerity Automatic Equipment Co., Ltd undertakes all maintenance duties for mass flow meter facilities and organizations and conducts all the security and surveillance for the properties.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect