Abstract: how to correctly install ultrasonic flowmeter scale information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Ultrasonic flowmeter display instrument if installed in indoor should choose to avoid interference sources such as frequency conversion control cabinet, power cleaner 220 v due to the installation position of sensor, the state of the pipeline under test has a great influence on the accuracy of measurement, so please choose to satisfy the following conditions. More flow meter manufacturers choose model price quote you are welcome to inquire, here is how to correctly install ultrasonic flowmeter scale article details. Ultrasonic flowmeter display instrument if installed in indoor should choose to avoid interference sources such as frequency conversion control cabinet, power cleaner 220 v due to the installation position of sensor, the state of the pipeline under test has a great influence on the accuracy of measurement, so please choose the place of the following conditions. 1, pipe roundness is good, the inner surface is smooth, uniform wall. 2, upstream side 5 d, downstream side more than 3 d straight pipe, note & other; D for pipe diameter & throughout; 。 3, the line must be filled with liquid to be tested. 4, there must be enough space is easy to ultrasonic flowmeter sensor installation and operation. 5, in a horizontal pipe to be tested, the top and bottom of the sensor should not be installed in the pipeline, and avoid uneven pipe and weld. Ultrasonic flowmeter sensor installation 1, around the intended installation position than, the area of the sensor is about twice as large as the paint on the wall, rust, dirt, such as clean, wipe out the metal should have no uneven. 2, according to figure 1, 2, install fasteners on the pipeline, should be fixed on the pipe with stainless steel belt, should not be loose. 3 good, laying cable from cable access hole to the junction box of the terminals. 4, each ultrasonic flowmeter sensor transducer positive, coated with a thick layer of coupling agent ( Butter) Transducer, the sensor surface contact with the wall, placed in the fastening components, pressure and the pressure plate will sensor, coupling agent should from the sensors in the cracks around the extrusion, form a sealing strip. Fastening bolt knob tightly, pay attention to four bolt the strength should be uniform, do not make the sensor offset. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
are an important part of the society and they come in handy in any place where there are coriolis density meter in need of tuning fork liquid density meter.
Energetic, optimistic entrepreneurs often tend to believe that sales growth will take care of everything, that Beijing Sincerity Automatic Equipment Co., Ltd will be able to fund our own growth by generating profits.
Many homeowners find that they can cut costs while keeping home cool efficiently with .
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com