Abstract: The information on how to select the S-type load cell is provided by the excellent flowmeter and flowmeter production and quotation manufacturers. Sensor selection can be divided into structure, shape, and output signal to select different sensors. Sensors vary widely in principle and structure. How to choose a sensor reasonably according to the specific measurement purpose, measurement object and measurement environment is a certain amount. For more flowmeter manufacturers to select models and price quotations, you are welcome to inquire. The following is the details of the article on how to select S-type load cells. Sensor selection can be divided into structure, shape, and output signal to select different sensors. Sensors vary widely in principle and structure. How to choose a sensor reasonably according to the specific measurement purpose, measurement object and measurement environment is the measurement of a certain quantity. The first problem to be solved. After the sensor is determined, the corresponding measurement method and measurement equipment can also be determined. The success or failure of the measurement results depends to a large extent on whether the selection of the sensor is reasonable. Youzhongli Technology will briefly describe several principles for selecting S-type load cells: 1. Determine the type of S-type load cells according to the measurement object and measurement environment: to carry out—For a specific measurement work, we must first consider which principle sensor is used, which can only be determined after analyzing various factors. Because, even for measuring the same physical quantity, there are sensors with various principles to choose from. Which sensor is more suitable, you need to consider the following specific issues according to the characteristics of the measured and the conditions of use of the sensor: the size of the range; The requirements of the measured position for the sensor volume; whether the measurement method is contact or non-contact; the signal extraction method, wired or non-contact measurement; the source of the sensor, whether it is domestic or imported, and whether the price is affordable, or self-developed. After considering the above problems, it is possible to determine which type of sensor to choose, and then consider the specific performance indicators of the sensor. 2. S-type load cell stability The ability of the sensor to keep its performance unchanged after a period of use is called stability. In addition to the structure of the sensor itself, the factors affecting the long-term stability of the sensor are mainly the use environment of the sensor. Therefore, to make the sensor have good stability, the sensor must have strong environmental adaptability. Before selecting a sensor, the use environment should be investigated, and the appropriate sensor should be selected according to the specific use environment, or appropriate measures should be taken to reduce the impact of the environment. The stability of the sensor has quantitative indicators. After the period of use, it should be re-calibrated before use to determine whether the performance of the sensor has changed. In some occasions where the sensor is required to be used for a long time but cannot be easily replaced or calibrated, the selected sensor has stricter stability requirements and must be able to withstand the test of a long time. 3. The accuracy of the S-type load cell is an important performance index of the sensor, and it is an important link related to the measurement accuracy of the entire measurement system. The higher the accuracy of the sensor, the more expensive it is. Therefore, the accuracy of the sensor only needs to meet the accuracy requirements of the entire measurement system, and it is not necessary to select it too high. This makes it possible to choose a cheaper and simpler sensor among many sensors for the same measurement purpose. If the purpose of measurement is qualitative analysis, a sensor with high repeatability can be selected, and it is not appropriate to use a sensor with high absolute value accuracy; if it is for quantitative analysis, it is necessary to obtain accurate measurement values, and it is necessary to select a sensor with an accuracy level that meets the requirements. 4. S-type load cell frequency response characteristics The frequency response characteristics of the sensor determine the frequency range to be measured, and must maintain undistorted measurement conditions within the allowable frequency range. In fact, the response of the sensor always has—Set the delay, I hope the delay time is as short as possible. The frequency response of the sensor is high, the frequency range of the measurable signal is wide, and due to the influence of the structural characteristics, the inertia of the mechanical system is large, and the frequency of the measurable signal of the sensor with low frequency is low. In dynamic measurement, the response characteristics should be based on the characteristics of the signal (steady-state, transient, random, etc.) to avoid excessive errors. 5. Linear range of S-type load cell The linear range of the sensor refers to the range in which the output is proportional to the input. Theoretically, within this range, the sensitivity remains constant. The wider the linear range of the sensor, the larger its range, and can guarantee a certain measurement accuracy. When selecting a sensor, when the type of the sensor is determined, it first depends on whether its range meets the requirements. But in fact, no sensor can guarantee absolute linearity, and its linearity is also relative. When the required measurement accuracy is relatively low, within a certain range, the sensor with less nonlinear error can be approximately regarded as linear, which will bring great convenience to the measurement. 6. Selection of the sensitivity of the S-type load cell Generally, within the linear range of the sensor, it is hoped that the higher the sensitivity of the sensor, the better.
There are a wide variety of which are scientifically tested to have positive effects on the ability to electromagnetic flow meter slurry. tuning fork liquid density meter mass flow meter is one of them.
Exceed customers' expectations in the procedures of manufacturing mass flow meter.
The first step toward Sincerity’s successful selling campaign is to understand your customers. What are their needs or desires? Why would they support your product? Even more importantly, why would they be passionate about your product?
Increasing consumer awareness and rising concern about improving vortex flow meter manufacturer are driving the market of products.
Armed with professional team and advanced equipment, Beijing Sincerity Automatic Equipment Co., Ltd is specialized in offering high quality in various designs. Visit us at Sincerity Flow Meter to find your desired .
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com