Abstract: The information on how to calibrate the metal rotor flowmeter is provided by the excellent flowmeter and flowmeter production and quotation manufacturers. Calibration of remote metal tube rotameter It is impossible to calibrate metal tube rotameter by conventional methods, which is determined by the structural principle of the transmitter. Because the metal tube rotameter is between the input pressure source and the resulting 4-20mA current signal. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the details of the article on how to calibrate the metal rotor flowmeter. Calibration of remote metal tube rotameter It is impossible to calibrate the metal tube rotameter by conventional methods, which is determined by the structural principle of the transmitter. Because the metal tube rotameter is between the input pressure source and the generated 4-20mA current signal, in addition to machinery and circuits, there is also a microprocessor chip that operates on the input data. Therefore, the adjustment is different from the conventional method. In fact, the manufacturer also has instructions on the calibration of the metal tube rotor flowmeter. The series of transmitters sold by our company have:“set range”,“Weight range”,“fine-tuning”points. in“set range”Operation is mainly through LRV. URV digital settings to complete the configuration work, and“Weight range"Operation requires connecting the transmitter to a standard pressure source, guided by a series of commands, with the transmitter directly sensing the actual pressure and setting the value. The initial and final setting of the range is directly dependent on the actual pressure input value. However, see that although the analog output of the transmitter is correctly related to the input value used, the digital readout of the process value will show a slightly different value, which can be calibrated by trimming. Since each part of the metal tube rotameter needs to be adjusted individually and must be adjusted jointly, the actual calibration can be carried out as follows: First, make a 4-20mA fine-tuning to correct the D/A converter inside the transmitter , since it does not involve sensing components, no external pressure signal source is required. Do a full fine-tuning again to make the 4-20mA, digital readout match the actual applied pressure signal, so a pressure signal source is required. Finally, make the re-quantity range, and make the analog output 4-20mA match the external pressure signal source through adjustment, and its function is exactly the same as that of the zero (Z) and range (R) switches on the transmitter shell. Some people think that the range of the metal tube rotameter can be changed as long as the HART Communicator is used, and the adjustment of the zero point and the range can be performed without the need to input a pressure source, but this method cannot be called calibration, only called calibration. for“set range”. True calibration requires a standard pressure source input to the transmitter. Because range adjustment (LRV, URV) is not a calibration without the use of a standard, output adjustment (transmitter conversion circuit) ignoring the input part (pressure input to the transmitter) is not a correct calibration. Furthermore, the relationship between pressure and differential pressure detection components, A/D conversion circuit and current output is not equal. The purpose of calibration is to find out the changing relationship of the three. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'How to calibrate the metal rotor flow meter'
The average consumer is always looking for ways to save money while finding out solutions, is designed for killing two birds with one stone, providing a perfect solution to mass flow meter problems.
We have professional skills and advanced facilities in mass flow meter and many years of experience in endress hauser coriolis mass flow meter industry. Choose our products at Sincerity Flow Meter, and you will get supreme buying experience in return.
Beijing Sincerity Automatic Equipment Co., Ltd have significantly changed the way customers approach manufacturing. mass flow meter can still compete if we are willing to change the ways in producing.
Using high technology, mass flow meter showed its competitive advantages, captioned with information about the company's commitment to providing safe, reliable, profitable jobs to local artisans.
can be used in a wide variety of ways.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com