loading

Sincerity Group | Coriolis flow meter manufacturers| 

Golden lotus 10 of intelligent vortex flow meter scale installation requirements

by:Sincerity Group     2021-07-18
Abstract: golden lotus 10 of intelligent vortex flow meter scale installation requirement information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Abstract: the vortex flowmeter can be widely used in large, medium and small various water supply and drainage pipe, industrial circulation, sewage treatment, oil and chemical reagents and compressed air, saturation and superheated steam, gas and all kinds of medium flow rate measurement and can be used as flow transmitting. More flow meter manufacturers choose model price quote you are welcome to inquire, here is a golden lotus describes intelligent vortex flow meter scale installation ten requirements of article for details. Vortex flowmeter can be widely used in large, medium and small various water supply and drainage pipe, industrial circulation, sewage treatment, oil and chemical reagents and compressed air, saturation and superheated steam, gas and all kinds of medium flow rate measurement and can be used as flow transducer is applied to automatic control system, the block using EEPROM to power-fail protection of cumulative flow, protection for more than 10 years. During the installation process, there is always some problems, many people react that it involves a lot of knowledge, this paper lists some installation requirements for you about the information, for reference only. Vortex flowmeter can be widely used in large, medium and small various water supply and drainage pipe, industrial circulation, sewage treatment, oil and chemical reagents and compressed air, saturation and superheated steam, gas and all kinds of medium flow rate measurement and can be used as flow transducer is applied to automatic control system, the block using EEPROM to power-fail protection of cumulative flow, protection for more than 10 years. Vortex street flowmeter installation note key points: 1, choose the installation site and environment to avoid strong power equipment, high-frequency equipment, strong power switch device; To avoid the influence of high temperature heat source and the radiation source, to avoid strong vibration and strong corrosive environment and so on, at the same time to consider easy installation and maintenance. 2, upstream and downstream must have enough if straight pipe upstream of sensor installation points on the same plane has two 90. Elbow, are: straight pipe upstream & ge; 25 d, the downstream straight pipe & ge; If 5 d sensors installed upstream of point in different plane has two 90. Elbow, are: straight pipe upstream & ge; 40 d, downstream straight pipe & ge; 5 d regulating valve should be installed on the downstream side of the sensor outside 5 d, if must be installed in the upstream of the sensor, the sensor straight pipe upstream should be not less than 50 d, downstream should be not less than 5 d. 3, installation point of upstream and downstream piping should be concentric with sensor, coaxial deviation should be no less than 0. 5 dn4, pipes, adopt measures to reduce vibration sensor to avoid installed in strong vibration, transverse vibration in particular. If need to install the anti-vibration measures must be taken, respectively at the upstream and downstream of sensor 2 d piping fastening device, and vibration-proof pad. Installed in horizontal pipe runs is flow sensor zui installation method in common use. Measuring gas flow rate, if contain a small amount of fluid in the gas being measured, the sensor should be installed in the pipeline is relatively high. Measurement of liquid flow, if the liquid contains a small amount of gas being measured, the lower part of the sensor should be installed in the pipeline. Sensor installation of measuring gas flow in vertical pipe, the sensor can be installed in vertical pipe runs, flow to the unlimited. If the measured gas containing a small amount of liquid, gas flow should be from the bottom up. Measuring the liquid flow rate, liquid flow shall be from the bottom up: it won't attach additional liquid weight on the probe. 7, sensors in a horizontal pipe side regardless of what kind of fluid measurement, the sensor can be in the upper horizontal pipeline, especially the measurement of superheated steam and saturated steam and low temperature liquid, if the condition allows zui to good use side, so the temperature of the fluid have less effect on the amplifier. Sensors in a horizontal pipeline inversion generally do not recommend using this installation method. This installation method is not applicable to measure the general gas, superheated steam. Can be used for measurement of saturated steam, high temperature suitable for measuring the liquid or frequent cleaning pipelines. Sensors in insulation pipe on the installation of measuring high temperature steam, thermal insulation layer zui much no more than a third of the bracket height. Pressure and temperature measuring points selection according to the needs of measurement, to be near the sensor to measure the pressure and temperature, the pressure measuring point should be in 3 - sensor downstream 5 d, temperature measuring points should be 6 - of the downstream of the sensor 8 d. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd will continue to build a corporate culture that respects and values the unique strengths and cultural differences of our associates, customers and community.
If you want to know more about finding the proper for fork density meter manufacturer solutions, visit Sincerity Flow Meter.
Beijing Sincerity Automatic Equipment Co., Ltd sells endress hauser ultrasonic flow meter and yet their focus on operational excellence and mastery of distributed manufacturing facilities vortex flow meter manufacturer has made them the dominant player in the space.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: