loading

Sincerity Group | Coriolis flow meter manufacturers| 


Gas Turbine Flow Meter Flow Channel Pressure

Abstract: Gas turbine flowmeter flow channel pressure information is provided by excellent flowmeter and flowmeter manufacturers and quotation manufacturers. 1 Basic structure and working principle of turbine flowmeter This paper adopts CNiM-TM series 80mm diameter gas turbine flowmeter of Cangnan Instrument Factory as the research object, and carries out numerical simulation of the pressure loss of the internal flow channel. The schematic diagram of the gas turbine flowmeter is shown in the figure. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the details of the gas turbine flowmeter flow channel pressure article. 1 Basic structure and working principle of turbine flowmeter In this paper, the CNiM-TM series 80mm diameter gas turbine flowmeter of Cangnan Instrument Factory is used as the research object, and the numerical simulation of the pressure loss of the internal flow channel is carried out. The schematic diagram of the gas turbine flowmeter is shown in Figure 1. The actual gas turbine flowmeter is shown in Figure 2, of which Figure 2(a) is the actual picture of the turbine flowmeter, and Figure 2(b) is the actual picture of the impeller of the turbine flowmeter movement. Fig.1 Structural diagram of gas turbine flowmeterFig.2 Actual diagram of turbine flowmeter and impeller The relationship between , the fluid velocity is obtained by measuring the impeller speed, and then the flow value in the pipeline is obtained. The pulse frequency f output by the turbine flowmeter is proportional to the measured volume flow qv, namely (1) In formula (1): k—The meter factor of the flowmeter. According to the law of motion, the motion equation of the impeller can be written as (2) In formula (2): J—The moment of inertia of the impeller; t—time; ω—Rotational speed of the impeller; Tr—Pushing torque; Trm—Mechanical frictional resistance torque; Trf—Flow resistance torque; Tre—Electromagnetic resistance torque. 2 Calculation model 2.1 Mathematical model The working medium of the numerical simulation of the turbine flowmeter is air, and the flow is in turbulent flow. The numerical simulation turbulence model adopts the Realizable K-ε model, which is suitable for simulating and calculating the boundary of rotating flow and strong inverse pressure gradient Laminar flow, flow separation and secondary flow, etc., the model equations are expressed as:——Average flow velocity in all directions; a—speed of sound;μ—dynamic viscosity coefficient;υ—Kinematic viscosity coefficient; K—Turbulent kinetic energy; ε—Turbulent dissipation rate;βT—expansion coefficient; ωk—angular velocity;—Time-average rotation rate tensor; if the influence of buoyancy is not considered, Gb = 0, if the flow is incompressible, = 0, YM = 0. 2.2 Meshing of the fluid area Use Solidworks three-dimensional design software to build the turbine flowmeter components according to the actual size Die and assembly, simplify the parts that have less influence on the fluid area, such as the spindle, the pressure hole and the oil filling hole. First perform Boolean operation on the movement part to obtain a pure fluid area, then add an envelope to the impeller to form a rotating area, and add a straight pipe section 15 times the diameter of the movement before and after the inlet and outlet of the movement to ensure that the flow at the inlet and outlet is fully developed Turbulence. The entire fluid area includes the front and rear straight pipe sections, the impeller envelope and the fluid area of ​​the core part. Use Gambit software to mesh the 3D model, optimize and simplify the parts that are difficult to generate meshes such as small faces and sharp corners in the fluid area. Areas with more complicated flow conditions such as impellers are locally encrypted, as shown in Figure 3. Among them, Figure 3(a) is the grid diagram of the fluid area of ​​the core, and Figure 3(b) is the grid diagram of the impeller. The total number of grids is about 2.3 million. Figure 3. Turbine flowmeter fluid area grid. Figure 2.3 Numerical simulation simulation condition setting. During numerical calculation, in order to facilitate the comparison between simulation results and experimental results, the settings of ambient temperature, humidity and pressure are the same as the experimental conditions. densityρand dynamic viscosityηAccording to the calculation procedure proposed by Rasmussen, the simplified formulae (5) and (6) derived by fitting are calculated and obtained: (6) In formula (5) (6): T—temperature; P—pressure; H—humidity. The solver adopts the separation, implicit and steady-state calculation methods. The turbulence model selects the Realizablek-ε turbulence model, and the pressure interpolation adopts the Body force weighted format. The turbulent kinetic energy, turbulent dissipation term and momentum equation are all discretized by the second-order upwind style. The coupling of the velocity is solved by the SIMPLEC algorithm, and the rest of the settings are the default values ​​of Fluent. The inlet of the pipeline in the calculation area adopts the velocity inlet boundary condition, and the velocity direction is perpendicular to the cross section of the inlet straight pipe section. The outlet boundary condition adopts the pressure outlet. The impeller envelope is set as the dynamic flow area, and the rest is the static flow area. The interface boundary condition is used as the interface, and the multiple reference coordinate model (MRF) is used for the coupling between the rotating part and the static part.

Technology is a foundational component of today's fast-paced business environment. Beijing Sincerity Automatic Equipment Co., Ltd who are digital natives are especially equipped to harness technology's power to establish, promote and grow our businesses.

For more information on this topic and others, please visit Sincerity Flow Meter. We are among the top manufacturers of mass flow meter u shape coriolis mass flow meter in China, and we serve big names in mass flow meter industry. You can rely on us for our high quality . Send your enquiry!

Do you want to find a provider to get your mass flow meter problem settled? If so, we suggest that you give a shot to Beijing Sincerity Automatic Equipment Co., Ltd. Visit Sincerity Flow Meter to learn more and contact us.

rosemount coriolis mass flow meter problems are nothing new, almost every one of us have to go through them at some point of our lives and some of us never get rid of them. with the development of endress hauser ultrasonic flow meter technology, now provides a perfect cure for that.

There have been conclusive evidence on 's role in tuning fork liquid density meter and low flow turbine flow meter.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect