loading

Sincerity Group | Coriolis flow meter manufacturers| 


Flow meter selection must be considered

Abstract: The selection of flow meter must consider the information provided by the excellent flow meter and flow meter production and quotation manufacturers. The continuous development of the domestic economy and the country's series of measures to save energy consumption have further promoted the demand for flow meters. Especially in the measurement of urban natural gas, coal gas, industrial steam and other various mediums and the internal cost accounting of each order, it is all forced. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the articles that must be considered in the selection of flowmeters. The continuous development of the domestic economy and the country's series of measures to save energy consumption have further promoted the demand for flow meters. Especially in the measurement of urban natural gas, coal gas, industrial steam and other various media and the internal cost accounting of each single, there is an urgent need for measuring instruments with a wide range, high precision and high reliability. Differential pressure flowmeter ranks first in the flowmeter list with its advantages of mature technology, simple structure, no moving parts, stability and reliability, and adaptability to surface width. The composition of the differential pressure flowmeter At present, the differential pressure flowmeter has the following three composition methods: 1. An integrated differential pressure flowmeter, which integrates the throttling device, differential pressure, pressure, temperature, and calculation display into a whole flowmeter. The flow can be displayed directly from the meter, or the measured value can be transmitted remotely through the 4-20mA current. 2 Integrated differential pressure flow transmitter, install the differential pressure transmitter directly on the throttling device, and output a 4-20mA electrical signal representing the magnitude of the differential pressure signal. The flow calculation and temperature and pressure compensation are configured by the user. 3 It consists of a throttling device, a differential pressure transmitter, a pressure transmitter, a temperature transmitter, and a flow calculation and display instrument. Also known as a split differential pressure flowmeter. The third is the traditional composition of differential pressure flow meters, the use of which has dropped significantly in recent years. The second way cannot be called a flowmeter, it has no flow display or output, and is usually called an integrated differential pressure flow transmitter. It is suitable for use as a field instrument in a control system. The 4-20mA differential pressure signal is sent to the control system, and the measured flow is obtained after the control system calculates. The first is the true differential pressure flowmeter, which contains all the necessary elements of a flowmeter. It also represents the development direction of differential pressure flow meters. General principles for selecting flowmeters To correctly and effectively select flow measurement methods and instruments, one must be familiar with the instruments and the characteristics of the fluid being measured. At the same time, economic factors must also be considered. Generally speaking, there are five main factors: performance requirements, fluid characteristics, installation requirements, environmental conditions, and cost. There may be a variety of options for the instrument that can be used in a certain place. If you only make a rash decision based on past experience or simply consider a certain factor, you may lose the possibility of choosing the most suitable instrument. However, it is not a simple matter to combine these factors to come up with the optimal solution. Here are some suggestions based on our years of accumulation for your reference when choosing a flowmeter. 4 Accuracy Accuracy is a very important indicator of a flow measuring instrument, and it is also an important indicator that is easy to ignore in the process of meter selection. Easy to ignore here means that the user does not give further consideration to the accuracy proposed by the manufacturer when selecting the table. Regarding the accuracy of a certain watch indicated by the manufacturer, the question that needs to be further considered when selecting a watch is: 5 The percentage of error refers to the reference error (measurement upper limit or percentage of the range) or relative error. In addition, changes in temperature, pressure and environmental conditions used in the field will generate additional errors. When selecting, the comprehensive system error of the flowmeter should be pursued, and a single accuracy index should not be superstitious. 6 Whether the accuracy level indicated by the manufacturer is in line with common sense. Some manufacturers set the plug-in meter for measuring the flow rate of the plug-in vortex street, turbine, Venturi and other points as±1% or±1.5%. It is obviously unreasonable and belongs to the excessive exaggeration of extending the flow rate measurement accuracy of the insertion head to the flow measurement accuracy. 3. All flow meters except the standard throttling device are non-standard flow meters, and must be calibrated in real flow before leaving the factory to obtain the applicable flow coefficient, so it is necessary to understand the standard device. The ideal flow field of the flowmeter working in the industrial field is to fully develop the turbulent flow. Therefore, the instrument constants and accuracy levels obtained by real-flow calibration on a standard device with fully developed turbulent flow have practical significance. 4. As mentioned above, when choosing a flowmeter, it should pursue its comprehensive system error, rather than superstitious a single accuracy index. For example, what is the accuracy of the same flowmeter whose factory air is calibrated to 1% when it is used for steam measurement? It is a difficult question to answer, and the results will be very different if you choose watches from different manufacturers. The main problem is that the calculation of steam density is very different between manufacturers and various flowmeters. Some flowmeters do not even treat superheated steam and saturated steam differently, and mix the two into one pool, which is even more impossible to talk about. precision.

Owing to its endress hauser coriolis mass flow meter and insertion ultrasonic flow meter benefits, has become a buzzword in the v shape coriolis mass flow meter market.

With all the pros and cons of different in mind, click Sincerity Flow Meter to learn more about and decide which mass flow meter option is best for your case.

Beijing Sincerity Automatic Equipment Co., Ltd has extented its range of manufacturing scale, which satisfys customers' needs.

GET IN TOUCH WITH Us
recommended articles
The pharmaceutical industry is constantly evolving, and with this evolution comes the need for innovative technology to streamline processes and ensure accuracy.
Have you ever wondered how a Coriolis flow meter works? This intricate and precise piece of technology is essential in a wide range of industries, from oil and gas to food and beverage production.
Measuring mass flow rate is an essential process in various industries, including manufacturing, chemical processing, and oil and gas.
Mass flow meters are crucial tools in the chemical manufacturing industry.
Mass Flow Meters: Key Features and Considerations Before Purchase

When it comes to measuring the flow rate of fluids, mass flow meters are an essential tool in various industries, including oil and gas, chemical, pharmaceutical, and food and beverage.
ATEX flow meters are essential tools for monitoring and regulating fluid flow in hazardous environments.
As a language model AI, I can provide help on generating the article content, but I cannot control the length of the article nor its contents.
Selecting the Right ATEX Flow Meter for Flammable Material Applications

Are you in the market for an ATEX flow meter for flammable material applications but feeling overwhelmed by the options available? With so many factors to consider, choosing the right flow meter can be a daunting task.
Enhancing Quality Control with Coriolis Density Meters in Production

Quality control is a crucial aspect of any production process, especially in industries such as pharmaceuticals, food and beverage, and chemical manufacturing.
Coriolis mass flow measurement is a critical aspect of many industrial processes, as it allows for accurate measurement and control of fluid flow.
no data

WOULD YOU LIKE TO RECEIVE THE LATEST NEWS ABOUT TRENDS IN FLOW CONTROL ?

 

                 

Contact Us

Copyright © 2025 Beijing Sincerity Group . | Sitemap
Customer service
detect