loading

Sincerity Group | Coriolis flow meter manufacturers| 

Far eastone meter main points of installation and application scope

by:Sincerity Group     2020-12-24
Abstract: remote meter main points of installation and application scope of information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Far eastone meter is ordinary mechanical water meter and electronic collection and transmission module, electronic module completion signal acquisition, data processing, storage and data communications through the way to the repeater, or hand-held meter reading device. The table body adopts integrated design, it is ok. More flow meter manufacturers choose model price quote you are welcome to inquire, below is the remote meter main points of installation and application scope of the article details. Far eastone meter is ordinary mechanical water meter and electronic collection and transmission module, electronic module completion signal acquisition, data processing, storage and data communications through the way to the repeater, or hand-held meter reading device. Table body adopts integrated design, which can real-time will record and save the users, or directly read the current accumulative frequency, each meter has a code, when the intelligent water meter can will immediately after receive the meter reading instruction on the meter data to the management system of remote water meter installation points 1) , water meter should be installed in easy access and readings, not polluted by exposure, frozen, and mechanical damage. 2) , the front end of the screw vane meter should be 8 ~ 10 times of water meter nominal diameter of straight pipe, the other types before and after water meter, straight pipe should be not less than 300 mm. 3) , vertical screw vane rotor meter and meter should be installed; Horizontal screw vane and positive displacement meter according to actual situation to determine horizontal and inclined or vertical installation; When vertically mounted in the direction of flow must be from the bottom up. 4) And for the unity of life and production, fire water supply system, such as only a introduction of tube, by-pass pipe shall be installed around the water meter. 5) , water meter and the by-pass pipe shall be installed before and after repair valve, water meter and table after the valve should be installed drainage device. In order to reduce head loss and ensure the straight flow of the water table before the tube before the table maintenance appropriate USES gate valve. Household water meter in the house, the table after valve repair and special drainage device is not set. 6) Well, water meter should prevent flood and rain. 7) And the direction of the water meter should be consistent with the pattern of it. 8) , when the water meter reversal may occur and affect measurement and damaged water meter, should be set after a water meter check valve. 9) , hot and cold water meter installation requirements in addition to the operating temperature is different, basically the same. The biggest working temperature is 110 ℃ hot water meter. Jorge meter installed in front of the boiler and heat exchanger, to prevent backflow, should be set after a water meter check valve. 10) , remote meter installed there are two ways: only the function of outdoor meter remote water meter installation is relatively simple, as long as the will and installed on the outdoor water meter output system according to data from the device ( Repeater) Can be connected; Is another way to the building or the whole community of all remote meter through the repeater and network controller is connected to the community management, unified management through the terminal equipment. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Beijing Sincerity Automatic Equipment Co., Ltd is different from other companies as we provide timely and unique services to our respected clients.
Beijing Sincerity Automatic Equipment Co., Ltd intends to make enough profit to generate a fair return for our investors and to finance continued growth and development in mass flow meter.
There are so many factors that businesses have to weigh when producing mass flow meter, and we are not going to pretend to grasp all of them.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: