Abstract: the electromagnetic flow meter scale electromagnetic loss there is a variety of reasons information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Electromagnetic loss of electromagnetic flowmeter has a variety of reasons electromagnetic loss of electromagnetic flowmeter is a variety of reasons, the interference may exist around magnetic field and produce loss, may also be caused by the structure of the flow meter itself interference signal transmission speed, whatever the reason, one. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the electromagnetic flowmeter article details scale electromagnetic loss has a variety of reasons. Electromagnetic loss of electromagnetic flowmeter has a variety of reasons electromagnetic loss of electromagnetic flowmeter is a variety of reasons, the interference may exist around magnetic field and produce loss, may also be caused by the structure of the flow meter itself interference signal transmission speed, whatever the reason, in general, electromagnetic loss of electromagnetic flowmeter has the following several forms: hysteresis loss hysteresis loss is caused by hysteresis characteristics of magnetic materials. Coil is connected to alternating current (ac), due to the magnetic hysteresis phenomenon, phase lag phase than current certain Angle ( Hysteresis Angle) 。 When did not reach saturation of the magnetic induction intensity, magnetic hysteresis loss was small. Therefore, electromagnetic flowmeter using high magnetic permeability of magnetic yoke, core electrical silicon steel sheet, silicon steel sheet rolling direction zui the good and the magnetic field lines in the same direction, in this way, hysteresis losses fall greatly, can be neglected. Eddy current loss in the yoke of the eddy current loss yoke should adopt high magnetic permeability, low electric rate of chips, between each piece should be insulated, can reduce the loss, usually for dozens of Hertz mains frequency, the thickness of the silicon steel sheet is 0. 25 ~ 0. 5 mm can make the eddy current loss does not exceed the allowable value. Metal measuring tube eddy current loss of excitation power supply frequency is higher, the stronger the magnetic field intensity, the longer the magnetic field of the axial length and measure the tube diameter, wall thickness is thicker, the greater the eddy current is bigger, the greater the eddy current loss and magnetic induction strength lags behind that of the magnetic field current phase Angle. The company technical force is abundant, has a group of experienced theory and practice of automation instrument professionals, to provide customers from design, manufacture, selection and guide the installation, debugging and other services; Our company strictly follows the ISO9001:2000 international quality management system requirements, to provide users with quality excellent, exquisite workmanship of the diesel power and steam flowmeter flowmeter flowmeter product automation. Core part of imported components, large-scale microelectronics patch insulation technology and electrostatic spraying technology, and application of microprocessor technology for temperature compensation, the instrument measuring precision is improved, improved the temperature characteristic, expanded the range ratio, add the function of intelligent configuration, to further satisfy the operating requirements of field instruments. The company internal implementation according to the market demand, computer networking, information processing. Companies across the country have offices or distribution agents, sales and longevity and sound after-sales service network, to ensure that users in the design, installation and commissioning stage zui timely service. Company in line with to the & other; Meet customer demand, create value for customers throughout the &; Is the management idea, for many years in the steel, environmental protection, pharmaceutical, food, automobile, mining, construction machinery, water supply and drainage, oil and gas, chemical, metallurgy, water conservancy, electric power, thermal, paper making, municipal administration and other industries to provide users with a large number of a flow meter and the complete set of service, and to improve the timely after-sales service received the recognition from the market. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
The point for Beijing Sincerity Automatic Equipment Co., Ltd is that managerial processes are as important as other inputs in production and can create significant competitive advantage.
Beijing Sincerity Automatic Equipment Co., Ltd’s core aim is to afford high-quality products with the concept of manufacturing technology.
Beijing Sincerity Automatic Equipment Co., Ltd affords you a suitable low price for proving our ethical considerations.
Unlike the u shape coriolis mass flow meter, the is more flexibly used in accasions where tuning fork liquid density meter .
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com