Abstract: the electromagnetic flow meter scale and how to use the correct installation information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. How to use the electromagnetic flowmeter and correct installation: 1, the electromagnetic flowmeter should choose straight pipe full of liquid, such as the vertical section (line It is advisable to flow from the bottom up) Or fluid-filled pipes ( It is advisable to zui throughout the line below) , in the process of installation and measurement, no. More flow meter manufacturers choose model price quote you are welcome to inquire, here is how to use the electromagnetic flow meter scale and correct installation article details. How to use the electromagnetic flowmeter and correct installation: 1, the electromagnetic flowmeter should choose straight pipe full of liquid, such as the vertical section (line It is advisable to flow from the bottom up) Or fluid-filled pipes ( It is advisable to zui throughout the line below) , in the process of installation and measurement, the full package shall not happen; 2, measuring position should fall in more than 5 d and downstream straight section of 3 d; 3, choice of measurement point should be as far as possible away from the pump, valve and other equipment, to avoid the interference of measurement; 4, choice of measurement point should as far as possible away from the power station, strong magnetic field interference sources, etc. When installation, pay special attention to: the axis of the measuring electrode must be similar to horizontal direction; Measurement of the pipe must be completely filled with liquid. · The front of the flowmeter zui less 5 xaa meter diameter) The length of the straight pipe, the rear zui to have 3 xd (less D for flow meter diameter) The length of the straight pipe; For the convenience of installation and disassembly, installation of piping expansion joints after flowmeter. · The direction of fluid flow and the direction of arrow flowmeter; · The pipe must have the lining can be damaged by vacuum flowmeter, special attention should be paid; · Near the flow meter should be without strong electromagnetic field; · Near the meter should have ample space for installation and maintenance; · If there is vibration measuring pipe, on either side of the meter shall have a fixed support; · When measuring the mixed liquid of different medium hybrid point and the distance between the flowmeter zui to have less 30 & times; D( D for flow meter diameter) Length; · Cleaning and maintenance for the convenience of the flowmeter, the by-pass pipe should be installed, and also ensure before 5 d after 3 d flow of straight pipe. In measuring well flow meter installed in the way of 1, 2, 3 overflow pipe, entrance gate entrance 4, cleaning hole 5 meter. 6, short tube 7, 8, 9 bleed valve, drain valve & export middot; Such as the installation of ptfe lining flow time, connect two flange bolts should be paid attention to evenly tighten, otherwise easy to crush ptfe lining, zui to use torque wrench. Installation requirements shall be installed in the lower part of the horizontal and vertical place, avoid installed in pipe top and vertical zui touchpad; · Should be installed in the line up; · In open discharge pipe installation, should be installed in the pipeline is low; · If the pipe head more than 5 m, on the downstream side of the sensor installation exhaust valve; · Control valves should be installed on the downstream side of the sensor and the cut-off valve, and should not be installed on the sensor upstream; · Import and export, sensor must not be installed in the pump should be installed in the pump outlet; Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
Many of us have heard about mass flow meter and seen some of these units in operation in coriolis mass flow meter emerson, u shape coriolis mass flow meter and v shape coriolis mass flow meter spaces.
Beijing Sincerity Automatic Equipment Co., Ltd is an expert manufacturer that offers top-notch fork density meter manufacturer mass flow meter products in tuning fork liquid density meter. The company has a a lot of experience to offer quality ensured that cater to various customer demands. Simply visit Beijing Sincerity Automatic Equipment Co., Ltd website to learn more.
But we do think that reckoning with supply chains of mass flow meter is a really important step. Even super simple switches in material, or sourcing, or shipping, or worker benefits seems like good place to start.
Beijing Sincerity Automatic Equipment Co., Ltd is a initial company that supports expertise in searching marketing solutions.
We afford not only the best product but also the comprehensive service, satisfy the customer's demands.