Abstract: the electromagnetic flowmeter electrode daily maintenance information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. Electromagnetic flowmeter, electromagnetic flowmeter electrode electromagnetic flowmeter should be regular cleaning and cleaning method if the measured medium to long-term is dirty, so electromagnetic flowmeter in work after period of time, electrode nine will produce scale. When scaling material conductivity. More flow meter manufacturers choose model price quote you are welcome to inquire, here is the electromagnetic flowmeter electrode daily maintenance article details. Electromagnetic flowmeter, electromagnetic flowmeter electrode electromagnetic flowmeter should be regular cleaning and cleaning method if the measured medium to long-term is dirty, so electromagnetic flowmeter in work after period of time, electrode nine will produce scale. When scaling material conductivity and electrical conductivity of the measured medium is not at the same time, there would be a measurement error. Sludge, oil pollution of electrode, also can make the instrument output swing and drift. Therefore, in this case we need regular electrode electromagnetic flowmeter for maintenance and cleaning. We introduce several kinds of electromagnetic flowmeter electrode cleaning method for your reference. Electrode commonly used cleaning method has the following kinds: 1. Electrochemical methods of metal electrodes in electrochemical phenomena exist in the electrolyte fluid. According to the principle of electrochemistry, electrode electric field and fluid interface, electrode with fluid interface is electrode/fluid and is caused by the electric double layer. For electrodes and fluid interface electric field of the study found that the substance molecules, atoms, or ions adsorption phenomena in the interface has a rich or poor, and found that most of the inorganic anion surface active substances, as the typical ion adsorption rule, and inorganic cationic surface active is small. Therefore the electrochemical cleaning electrode anion adsorption is only considered. Anion adsorption and there is a close relationship between electrode potential and adsorption mainly in charge potential correction of potential range than zero, the electrode surface with opposite sign charge. On the electrode surface with no charge, when the remaining charge density slightly larger, electrostatic repulsion is greater than the adsorption force, anionic quickly stripping, this is the principle of electrochemical cleaning. 2. Machinery QingChuFa QingChuFa by installing special mechanical structure on the electrode to achieve clear electrode. There are two forms: one is to use mechanical abrasion. Made from stainless steel with a thin shaft scraper, through a hollow electrode spatula derivation, fine between shaft and the hollow electrode adopts mechanical seal in order to prevent the outflow of medium, then form the mechanical except the scraper. When rotating thin axis from the outside, scraper to tip plane turning, shave their dirt. This in addition to the scraper can be manually, also can use the automatic shave their fine motor drive shaft. Domestic electromagnetic flowmeter of Chinese and western AnYunYi scraper type electromagnetic flowmeter has this kind of performance, and stable performance, easy to operate. Another is in a tubular electrode, mount away dirt with the steel wire brush, shaft wrapped in sealed & other; O” Form circles, in order to prevent the fluid leaks. The cleaning device often need someone to pull wire brush to clean the electrode, is not very convenient to operate, not xi 'an YunYi scraper type electromagnetic flowmeter is convenient. 3. Cleaning method of ultrasonic generator to produce 45 ~ 65 KHZ ultrasonic wave voltage to the electrodes, the ultrasonic energy concentrated on the electrodes in contact with the medium, thus the ability of using ultrasound to shatter bilge, achieve the purpose of cleaning. 4. Electric shock tees this method USES ac high voltage to the electrodes and the medium between regularly, usually add 30 ~ 100 v. Because the electrodes are attached, the surface contact resistance, almost focused on attachments the applied voltage, high voltage attachments to breakdown, will then be flow away. Total safety, use electric shocks tees must be interruption of flowmeter measurement, signal lines disconnect between sensor and converter, power outage case ac high voltage directly on the sensor signal output terminal for cleaning. Above, this paper introduces several kinds of electromagnetic flowmeter electrode maintenance and cleaning method, in fact, if we are in the early stage of the selection can be measured after fully considering the medium can produce pollution to the electrode, then you should choose scraper type electromagnetic flow meter, can be very convenient to maintenance and cleaning of electrodes, save a lot of trouble. Xi 'an YunYi scraper type electromagnetic flowmeter, consists of display instrument, shell, the coil, the coil, electrodes and other components of the components, including electrode component is removable scraper type electrode structure, this structure is the signal electrode wear on the scraper blade scraper bar, through the gland nut will signal the electrodes and the scraper bar fixed on the electrode cup, cup welding electrodes, solid on the table, the signal electrode and the table inside body, electrode cup, separated by insulating material between the gland nut; When the signal electrode need maintenance and maintenance, need to open the cap, turn the handle with the hand, scraper bar rotates, make close to the signal electrode scraper scrape off the signal electrode on the surface of the dirt, clean up after the scraper in the direction of the spin to and the direction of fluid flow ( Is there direction mark on the knob) , the operation is very convenient.
Beijing Sincerity Automatic Equipment Co., Ltd has a professional team of engineers and technology professionals.
Check out offers at Sincerity Flow Meter and read exclusive reviews on latest insertion ultrasonic flow meter mass flow meter on our website.we are looking forward to creating mutual benefits with you.
Beijing Sincerity Automatic Equipment Co., Ltd is a initial company that supports expertise in searching marketing solutions.
A technology team created for insuring that mass flow meter is produced with the finest materials and technologies.
While the productivity and efficiency benefits of automation are unequivocal for manufacturing mass flow meter, the need for skilled humans to operate, utilize and advance technologies is equally unmistakable.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com