Abstract: The information on the countermeasures for the vibration of the metal tube rotameter at the installation site is provided by the excellent flowmeter and flowmeter manufacturers and quotation manufacturers. The metal tube rotameter, like other flowmeters, is used to test the flow parameters of gas or liquid. I have already mentioned a lot about the difference between the metal tube rotameter and its flowmeter, so everyone is concerned about such a test. instrument. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the article details of the countermeasures for the vibration of the metal tube float flowmeter at the installation site. The metal tube rotameter, like other flowmeters, is used to test the flow parameters of gas or liquid. I have already mentioned a lot about the difference between the metal tube rotameter and its flowmeter, so everyone is concerned about such a test. The instrument should already know a lot. However, when using this type of flowmeter with a float, everyone will encounter a problem, that is, the pointer of the flowmeter vibrates, so that the flow rate cannot be accurately detected. So how should the operator solve this situation? As mentioned earlier, when the surrounding objects do not vibrate, including the normal flow of the liquid in the pipeline, the metal tube float flowmeter vibrates because the float is stained Dirty dust. Then, as long as the operator finds the problem in time, the solution is very simple. The operator only needs to take out the metal tube rotameter, stop its operation first, then remove the impurities on the float, and remove the impurities in the float and the conduit. Cleaned up thoroughly, then the metal tube rotameter can be tested normally again. Therefore, when the pointer vibrates, there is no need to panic, the solution is very simple. During the use of the metal tube rotameter, if the site environment is corrosive acid or alkaline gas in the air, it will also have a certain corrosive effect on the flowmeter. Corrosion/rusting is the biggest defect of metal products, and Once the item begins to rust, its rust will continue, and then it will affect the equipment, which is very unfavorable to our equipment. As a metal measuring instrument, the metal tube rotameter is also prone to corrosion. Corrosion will not only affect our use effect, but also affect our service life, so we also need to deal with the rust situation of this watch? So how do we deal with it? This seems to be a user need to understand the problem. The first step is to start from the usual use work, that is to say, we should do a good job in the maintenance of the instrument in normal times, so as not to cause problems with the instrument quickly, and our use will also become more smoothly. And if rust starts to occur, then we need to spend a lot of energy to complete the rust treatment, and we can remove its rusted surface with cleaning agents. Or solve it in other ways. Metal tube rotameter still has the phenomenon that the float is stuck during use. Let's analyze why the float is stuck? How to deal with it? 1. If the float does not move, the pointer does not move. The float inside the tube body does not move, the follow-up magnet will not move, and the pointer of the metal tube float flowmeter will not move. Therefore, it is necessary to take out the float in the metal tube rotameter and analyze the cause of the stuck float. (1) Blocking of the float caused by the deformation of the stop Due to the careless opening and closing of the valve by the staff, the pressure of the flowmeter is too large and the stop of the flowmeter is deformed. Deformation of the stop will make the float inactive and the pointer not moving. (2) The cleanliness of the medium causes the sticking of the float The sticking of the float of the metal rotameter is also related to the cleanliness of the medium. Because there is magnetic steel in the float, if the medium contains iron chips, it will be adsorbed by the float, so the float will be stuck. Some fine particles will also make the float inflexible and stuck, so take out the float and clean it up. 2. The medium pressure is too small, so that the float cannot be lifted up. Because the metal tube float flowmeter is installed vertically in principle, the float has a certain gravity. If the medium pressure is too small, the natural float will not be able to stand up, and the pointer will not be able to move with the float. 3. The range selection is inappropriate. Each pipe diameter has a certain upper and lower limit of measurement. If the medium flow does not reach the lower limit of the flowmeter, the flowmeter will not indicate and the pointer will not move. The above is a simple analysis of the problem. If you have any questions, please communicate with us. Since the establishment of the factory for more than ten years, we have been committed to the research and development and production of flow meters and level meters. Over the years, we have not only sold products, but also An attitude and service, focusing on the customer's experience, really starting from the customer's point of view,Strive to achieve consistent pre-sale and after-sale service! The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Countermeasures for Vibration Caused by Metal Tube Float Flow Meters at the Installation Site'
With new and upcoming social commerce technologies, the biggest change for mass flow meter marketers will be a shift in focus from branding to lead generation and conversion.
No, this isn't a wonder product and it won't be likely to change your life but it will give your u shape coriolis mass flow meter a kick and bring the extraordinary to the every day. give it a shot at Sincerity Flow Meter.
With wide range of [分类关键词] products of top quality in offer, Beijing Sincerity Automatic Equipment Co., Ltd will definitely be your best option for mass flow meter solution. Do feel free to contact us at Sincerity Flow Meter.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com