loading

Sincerity Group | Coriolis flow meter manufacturers| 

Correct use and installation method of integrated orifice flow meter

by:Sincerity Group     2023-03-25
Abstract: The information on the correct use and installation method of the integrated orifice flow meter is provided by the excellent flow meter and flow meter manufacturers. Introduction to the correct use and installation method of integrated orifice flowmeter Jinhu Hongchuang Instrument Co., Ltd. has rich experience and installation experience, and has been engaged in instrument production for many years. The main products are: integrated orifice flowmeter, vortex flowmeter, electromagnetic flowmeter gauge, metal. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the correct use and installation method of the integrated orifice flowmeter. Introduction to the correct use and installation method of integrated orifice flowmeter Jinhu Hongchuang Instrument has rich experience and installation experience, and has been engaged in instrument production for many years. The main products are: integrated orifice flowmeter, vortex flowmeter, electromagnetic flowmeter, Metal tube rotameter. What are the precautions for using the integrated orifice flowmeter? The integrated orifice flowmeter is a new generation of flowmeter that integrates the detection functions of flow, temperature and pressure, and can automatically compensate for temperature and pressure. It adopts advanced microcomputer technology and new micro-power consumption technology. Simple to operate and easy to use. The integrated orifice flowmeter consists of three parts: sensing, transmission, and operation display. It is mainly suitable for industrial measurement of saturated steam, superheated steam, compressed air, mixed non-flammable and explosive gases and hot water, and the flow measurement of the above fluids. , display, measurement and online automatic control of the production process can be used. The most important thing to pay attention to when putting into operation is that the pressure guiding pipe must be filled with water or injected with high temperature steam to cool before starting operation. The straight pipe section before and after the throttling part of the integrated orifice plate flowmeter must be straight. The straight pipe section used to install the throttling part should be smooth. If it is not smooth, the flow coefficient should be multiplied by the roughness to correct the sparseness. A sufficiently long straight pipe section is required before and after the throttling piece, and the upstream side of the throttling piece is an open space or diameter≥In the case of a 2D large container, the length of the straight pipe between the open space or the large container and the throttle shall not be less than 30D (15D). If there are other local resistance parts between the throttling part and the open space or the large container, in addition to the specified minimum straight pipe length 1 between the throttling part and the local resistance part, from the open space to the throttling part The total length of the straight pipe section between the flow parts shall not be less than 30D (15D). How to use the integrated orifice flowmeter correctly: Jinhu Hongchuang Instrument will explain in detail below: 1. The pressure guiding pipe system is filled with cold water as the pressure guiding medium, and the measurement of high temperature steam is generally conducted through cold water. When the pipeline is not transporting steam, open the primary valve, pressure valve and balance valve, close the drain valve, and directly inject cold water from the water injection hole of the condensate tank until it is fully filled. Of course, the balance valve and pressure valve can also be closed, and the valve can be opened once to introduce high-temperature steam and slowly cool it into water. This method is generally not used because the steam temperature is too high and it is easy to damage the instrument. Special attention should be paid to the measurement of high temperature steam when the pressure guiding pipe is not filled with water or the temperature is very high and it is strictly prohibited to put it into operation. Measured compressed air and cold water directly use the medium pressure. 2. After the differential pressure transmitter is exhausted or drained, after the pressure guiding pipe is filled with water, sometimes a small amount of gas will accumulate in the pressure chamber of the differential pressure transmitter to affect the pressure guiding, which must be eliminated. Unscrew the bolts at the lower part of the positive and negative pressure chambers to drain the fluid. Generally, instruments newly put into operation do not need to be drained. Check that there is no leakage in the pressure guiding pipeline system, close all valves, and prepare to put into operation. Personalization: Shop: Company: The above is the whole content of this article. You are welcome to inquire about the selection and quotation of flowmeters of our factory. 'The correct use and installation method of the integrated orifice flow meter'
There is a strong need for more research on , in order to be able to provide strong and conclusive evidence of their u shape coriolis mass flow meter effects. However, recent studies have provided valuable insights into how the intake of may result in improved electromagnetic flow meter slurry.
The guiding vision of Beijing Sincerity Automatic Equipment Co., Ltd is 'Bringing the best to everyone we touch'. By 'The best', we mean the best products, the best people and the best ideas.
need fuel for energy,while endress hauser ultrasonic flow meter do not.
The team of engineers and developers at Beijing Sincerity Automatic Equipment Co., Ltd are the best in their own way and we promise to provide timely service to our esteemed clients.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: