Abstract: The correct installation information of gasoline flow meter is provided to you by excellent flow meter and flow meter manufacturers. Correct installation of gasoline flowmeter: As we all know, gasoline is a very volatile liquid, so when installing gasoline flowmeter, be sure to install it correctly to avoid unnecessary losses. The following is ABG Instrument Group's security for gasoline flow meters. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following are the details of the correct installation of gasoline flowmeters. Correct installation of gasoline flowmeter: As we all know, gasoline is a very volatile liquid, so when installing gasoline flowmeter, be sure to install it correctly to avoid unnecessary losses. Below are some of the Group's insights into gasoline flow meter installations. ①The transmitter should be installed in a dry and ventilated place indoors. Avoid installing in places with high ambient temperature, should not be subjected to strong vibration, and try to avoid equipment with strong magnetic fields, such as large motors, transformers, etc. Avoid installing in places with corrosive gas. The installation site is convenient for maintenance. This is the environmental condition to ensure the normal operation of the transmitter. ②In order to ensure that the measuring tube of the transmitter is filled with the measured medium, the transformer should be installed vertically, and the flow direction is from bottom to top. Especially for liquid-solid two-phase flow, it must be installed vertically. If only horizontal installation is allowed on site, it must be ensured that the two electrodes are on the same horizontal plane. ③ Valves and bypasses should be installed at both ends of the transmitter. ④ The AC potential of several millivolts measured by the electrode of the electromagnetic flow transmitter is based on the liquid potential in the transmitter. In order to stabilize the liquid potential and keep the equal potential between the transmitter and the fluid to ensure stable measurement, the transmitter casing and both ends of the metal pipe should be well grounded, and the converter casing should also be grounded. The grounding resistance cannot be greater than 10, and cannot be shared with the grounding wire of other electrical equipment. If it is not possible to ensure good contact between the transmitter housing and the metal pipes, use metal wires to connect them. And then reliable grounding. ⑤ In order to avoid interfering signals, the signal between the transmitter and the converter must be transmitted with shielded wires. It is not allowed to put the signal cable and the power cable in parallel in the same cable steel pipe. The length of the signal cable should generally not exceed 30m. ⑥ The installation site of the converter should avoid strong AC and DC magnetic fields and vibration, and the ambient temperature is—20-50℃, no corrosive gas, relative humidity not more than 80%. ⑦ In order to avoid the influence of the relative measurement of the flow rate, the flow control valve should be set downstream of the transmitter. For small-diameter transmitters, since the distance from the center of the electrode to the inlet end of the flowmeter is equivalent to several times the length of the diameter D, the upstream straight pipe may not be specified. However, for flowmeters with larger diameters, there should generally be a straight pipe section above 5D in the upstream, and generally no straight pipe section is required in the downstream. Over the years, we have been adhering to the“Based on service, guided by science and technology, with high-quality products and perfect solutions, we will pay the majority of users”With strong technical strength, strong market development awareness and perfect sales and service network, it has won a good reputation and praise from the leaders of the State Administration of Radio, Film and Television in the industry and the majority of users. This article comes from: Turbine flowmeter The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Proper Installation of Gasoline Flow Meter'
Sincerity needs to be able to reach social users in a way that complements what the brand is doing if they want to succeed at social commerce.
Interested in the that create such effect? Come to Sincerity Flow Meter to see some items.
Long gone are those days when low flow turbine flow meter were used to rosemount vortex flow meter. Now new like rosemount coriolis mass flow meter mass flow meter have come up.
According to the market analysts, exports from Beijing Sincerity Automatic Equipment Co., Ltd facilities in China will exceed the forecast.
The success of mass flow meter of campaigns largely rides on how you market your company to the crowd.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com