Abstract: the scale vortex flowmeter measurement considerations for compressed air information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. 1. Vortex street flowmeter properly installed properly installed sensors is to ensure that the first premise of measurement accurate and reliable, if on the installation location and the way to select error light person affect measuring accuracy, the person that weigh can affect the service life of the sensor, and even damage the sensor. (1). More flow meter manufacturers choose model price quote you are welcome to inquire, here is a compressed air note scale vortex flowmeter measurement details. 1. Vortex street flowmeter properly installed properly installed sensors is to ensure that the first premise of measurement accurate and reliable, if on the installation location and the way to select error light person affect measuring accuracy, the person that weigh can affect the service life of the sensor, and even damage the sensor. Straight pipe (1) to ensure proper installation of sensor, the length of straight pipe upstream of 15 - general requirements 40 dn, downstream length 5 dn, according to the situation of upstream and downstream piping appropriate adjustments, to ensure the accuracy of measurement. Sensor should also avoid the overhead of very long pipe installed on the sensor, after such a long time, because of the sensor sag easily between the sensor and the flange seal leakage, if necessary to install, must be set separately in the upstream and downstream of sensor 2 d pipe bracket fastening device, etc. (2) to avoid strong vibration sensor installation should be avoided in the strong line, if necessary to install, vibration reduction measures, which must be used at the upstream and downstream of sensor 2 d piping fastening device respectively, and anti-shock pad. In air compressor vibration at the exit is stronger, cannot install the sensors, shall be installed after the gas storage. (3) according to the measured fluid to choose the appropriate installation in high-pressure wind measurement, can choose to install the sensor in the horizontal line or vertical line, but if the high moisture content is higher in the wind, the level sensor when installation should be installed in the pipeline is relatively high, vertical installation gas flow should be from the bottom up. Whether horizontal or vertical installation, the direction of flow must be consistent with the sensor of the flow arrow on the table body. (4) avoid install the external environmental requirements of sensor temperature change a wide range of venues and equipment of thermal radiation, if must be installed, heat ventilation measures. In the damp, containing corrosive gas environment when installation, must be moistureproof and isolation measures. In addition, because the electrical noise interferes with the right of the sensor measurement, so the installation location to stay away from large power transformer, motor and other interference equipment. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
The use of electromagnetic flow meter slurry mass flow meter is a great trend in today's world. What you should know is that it has become a very important part of business today.
If you are looking for an excellent service in the UK then you can go to Beijing Sincerity Automatic Equipment Co., Ltd. They have almost everything what you might require for your endress hauser coriolis mass flow meter.
To find a qualified at reasonable price, contact Beijing Sincerity Automatic Equipment Co., Ltd at Sincerity Flow Meter, a professional provider and tell them what you envision for your mass flow meter.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com