Abstract: The application and installation information of Verabar flowmeters are provided by excellent flowmeter and flowmeter manufacturers and quotation manufacturers. Verabar flowmeter can be used to measure the flow of industrial water, filtered water, circulating water and other media in underground pipelines. Due to the large amount of impurities such as sediment, the temperature of the medium is not very high, generally at room temperature, and the pressure does not exceed 1.6Mpa. Fewer opportunities for process pipeline downtime. More flowmeter manufacturers choose models and price quotations. You are welcome to inquire. The following is the application and installation article details of Verabar flowmeters. Verabar flowmeter can be used to measure the flow of industrial water, filtered water, circulating water and other media in underground pipelines. Due to the large amount of impurities such as sediment, the temperature of the medium is not very high, generally at room temperature, and the pressure does not exceed 1.6Mpa. There are few opportunities for process pipelines to stop production, and there is basically no opportunity for pipelines to be stopped and empty. When we selected the model, the solution was to use the online installation type Verabar, these probes are easy to pull out and clean at any time. Of course, if the user's dust removal effect is good, we also recommend the off-line installation type with the back blowing device, which can cope with most situations. However, if it is necessary to pull out for maintenance, it can only be carried out when the production is stopped, unless a valve or a threaded bolt is specially equipped to block the welding head. Installation of Verabar flowmeter: Install it on a horizontal pipeline. When the medium is air and gas, Verabar should be installed on the upper 160°This ensures that the liquid in the gas will not enter the pressure guiding pipe. The transmitter must be installed at a position higher than the Verabar as much as possible, and the liquid draining operation is performed when the meter is turned on. In the case of liquid and steam, in the lower part 160°Any position of the liquid can allow any air bubbles to enter the pipeline. When conditions permit, it can only be installed in the upper part, and the exhaust operation is performed when the meter is opened (the underground pipeline is basically the same, in the case of silt in the underground pipeline, It is recommended that the probe should be installed vertically to ensure that the flow of the medium on both sides of the probe is similar, so that the pressure-taking hole is more difficult to block), for steam, condensate water is allowed to enter the pressure guiding pipe and flow into the condensing pipe. Location. For installation on vertical pipes, 360 can be installed around vertical pipes°Any position (to meet the straight pipe section), pay attention to correct the direction of the probe after installation, so that the direction of the fluid on the probe“→”With the pipe fluid direction kept at 3°within. Since the calculated differential pressure of the Verabar flowmeter is small, it is generally not necessary to discharge sewage. If the discharge is carried out for a long time, the balance state of the high-pressure pressure-taking hole of the probe will be broken, which will lead to the situation that the more the discharge is blocked, the more the low-pressure pressure will be taken. The hole is blocked, which means that the flow indicator is low after the meter is restarted. Therefore, it is usually emphasized that only system inspection and one-time zero-setting of the meter are performed during instrument maintenance work. For particularly important metering instruments, the Verabar probe can be cleaned regularly, such as Once/month, it is required to check the appearance of the probe and the dredging of the positive and negative pressure taking holes during cleaning. At the same time, in order to ensure the accurate measurement of the small differential pressure, it is necessary to ensure that the static sealing points of the measurement system are not leaking when the installation is restored. The above is the whole content of this article. You are welcome to inquire about the flowmeter selection and quotation of our factory. 'Application and Installation of Verabar Flow Meter'
are present in just about every facet of modern life.
The Global mass flow meter Leader. Beijing Sincerity Automatic Equipment Co., Ltd will build a unique portfolio of Sincerity and related brands, striving to surpass our competitors in quality, innovation and value, and elevating our image to become the mass flow meter company most customer turn to worldwide.
Like anything else in electromagnetic flow meter slurry, there are a variety of choices and types to choose from, and each of them will affect your budget in some form. Beijing Sincerity Automatic Equipment Co., Ltd offers a range of quality at competitive prices.
Deeper connections between Sincerity and mass flow meterare made when you go beyond the white lights of a corporate space.
Time is one of the biggest challenges cited by manufacturing mass flow meter.
Quick Links
Contact Us
● Add:No. 8 building, 3rd. district,I-Town, Gaoli Zhang
road,Haidian District, Beijing, China 100095
● Contact :Zoe Pan
Skype: testifypp
● Mobile:+86 13601110505
● Whatsapp : +86 18600270515
● Email:info@bjsincerity.com