loading

Sincerity Group | Coriolis flow meter manufacturers| 

An intelligent electromagnetic flowmeter scale installation method

by:Sincerity Group     2021-01-09
Abstract: an intelligent electromagnetic flowmeter scale installation method of information produced by excellent flow meter, flow meter manufacturer to offer you the quotation. An intelligent electromagnetic flowmeter installation method: 1, the horizontal and vertical sensor can be installed in a horizontal and vertical installation, but should make sure to avoid sediment and bubble influence on measuring electrode, electrode axial level as well. Should be installed vertically, fluid. More flow meter manufacturers choose model price quote you are welcome to inquire, here is one intelligent electromagnetic flowmeter scale installation method the article details. An intelligent electromagnetic flowmeter installation method: 1, the horizontal and vertical sensor can be installed in a horizontal and vertical installation, but should make sure to avoid sediment and bubble influence on measuring electrode, electrode axial level as well. Vertical installation, fluid flows from bottom to top. Sensor cannot be installed in the pipeline zui high position, the position of the accumulation of bubbles. 2, to ensure the full pipe installation to ensure that the flow sensor in the measurement, the pipe is filled with flow body, cannot appear the full package. Such as pipeline is not full package or exports have empty state, the sensor should be installed on a siphon. 3, bent pipe, valve and pump is installed between the intelligent electromagnetic flowmeter in order to guarantee the stability of the measurement, straight pipe should be set up before and after of the sensors, such as do the current stabilizer should be adopted or reduce the sectional area of measurement point. 4, not sensor installed at the inlet of the pump to avoid negative pressure, the sensor cannot be installed in the inlet of the pump, and should be installed at the outlet of the pump. 5, sensors, straight section of the straight section of import and export of ideal installation location should choose enough straight pipe before and after the measurement point. Imported straight section should & ge; 5 d, export straight pipe & ge; 3D( D for sensor of nominal diameter) 。 Plug-in imported straight section should & ge; Straight section of 20 D, export & ge; 7D( D for sensor of nominal diameter) 。 6, the installation of pipe exports to empty when the export is empty state, sensor should not be installed in the empty place, should be installed in low. Below the sensor installed in the pipeline, should guarantee the sensor inside is filled with liquid, cannot appear atc. 7, several sensors installed in series and parallel if need in series in sequence in the same line, the distance between each sensor shall be at least 2 the length of the sensor. If two or more sensors installed in parallel, each other the distance of the sensor must be greater than 1 m. The above seven is the intelligent electromagnetic flowmeter installation method. Above is all there is in this article, you are welcome to inquire me manufacturer flowmeter selection, quotation, etc.
There are a lot of businesses today that are very much in demand and one of them is a mass flow meter.
To understand how efficiently works, go to Sincerity Flow Meter for more information.
The first machine to produce low flow turbine flow meter, the insertion ultrasonic flow meter mass flow meter was invented in fork density meter manufacturer in vortex flow meter manufacturer by electromagnetic flow meter slurry and was subsequently improved.
Latest technology and manufacturing equipment has improved the quality of mass flow meter.
Custom message
Chat Online
Chat Online
Leave Your Message inputting...
Sign in with: